| 0280 D 020 BN4HC /-SFREE | HYDAC | 20 µm | 69 mm (2.7 in) | 356 mm (14 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0280 D 020 ON | HYDAC | 20 µm | 69 mm (2.7 in) | 356 mm (14 in) | ON=Optimicron low-press. | — | |
| 0280 D 025 W | HYDAC | 69 mm (2.7 in) | 371 mm (14.6 in) | W=Stainless Steel Wire Mesh | Main Filter MF0920660, MF0576270 | ||
| 0330 D 003 BH4HC /-SFREE | HYDAC | 3 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | — | |
| 0330 D 003 BH4HC /-V | HYDAC | 3 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | — | |
| 0330 D 003 BH4HC | HYDAC | 3 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060338, MF0920719 | |
| 0330 D 003 ECO/N | HYDAC | 3 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ECO/N=ECOmicron | — | |
| 0330 D 003 ON /-SFREE | HYDAC | 3 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 003 ON | HYDAC | 3 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 005 BH4HC /-SFREE | HYDAC | 5 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | — | |
| 0330 D 005 BH4HC | HYDAC | 5 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060340, MF0920723 | |
| 0330 D 005 ON /-SFREE | HYDAC | 5 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 005 ON | HYDAC | 5 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 010 BH4HC /-SFREE | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | — | |
| 0330 D 010 BH4HC /-V | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | — | |
| 0330 D 010 BH4HC | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060342, MF0920712 | |
| 0330 D 010 BN/AM | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BN/AM=Beta/Aquamicron | — | |
| 0330 D 010 ECO/N | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ECO/N=ECOmicron | — | |
| 0330 D 010 G/HC | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | G/HC=Lubimicron for API | — | |
| 0330 D 010 MM | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | MM=Mobilemicron | — | |
| 0330 D 010 ON /-SFREE | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 010 ON /-V | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 010 ON | HYDAC | 10 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0330 D 020 BH4HC | HYDAC | 20 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060344, MF0920716 | |
| 0330 D 020 ON | HYDAC | 20 µm | 91 mm (3.6 in) | 164 mm (6.5 in) | ON=Optimicron low-press. | — | |
| 0400 DN 003 BH4HC /-SO882 | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| >0400 DN 003 BH4HC (USE 2213976) | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 003 BH4HC /-V-SFREE-SO882 | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 003 BH4HC /-V-SO882 | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 003 BN4HC /-SO882 | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| >0400 DN 003 BN4HC (USE 2213968) | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 003 BN4HC /-V-SO882 | HYDAC | 3 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 006 BH4HC /-SO882 | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| >0400 DN 006 BH4HC (USE 2213977) | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 006 BH4HC /-V-SO882 | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 006 BN4HC /-SO882 | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| >0400 DN 006 BN4HC (USE 2213969) | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 006 BN4HC /-V-SO882 | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 006 ON/PS | HYDAC | 6 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | ON/PS=OptimicronN Pulse | — | |
| 0400 DN 010 BH4HC /-SO882 | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| >0400 DN 010 BH4HC (USE 2213978) | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 010 BH4HC /-V-SO882 | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 010 BN4HC /-SO103H | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 010 BN4HC /-SO882 | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| >0400 DN 010 BN4HC (USE 2213970) | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 010 BN4HC /-V-SFREE | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 010 BN4HC /-V-SO882 | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 010 MM | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | MM=Mobilemicron | — | |
| 0400 DN 010 ON/PO | HYDAC | 10 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | ON/PO=Optimicron® Power | — | |
| 0400 DN 020 BN4HC | HYDAC | 20 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 020 ON/PO /-V | HYDAC | 20 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | ON/PO=Optimicron® Power | — | |
| 0400 DN 025 BH4HC /-SO882 | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 025 BH4HC /-V-SO882 | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0400 DN 025 BN4AM /-V | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 025 BN4HC /-SFREE | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 025 BN4HC /-SO882 | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| >0400 DN 025 BN4HC (USE 2213971) | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 025 BN4HC /-V-SO882 | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0400 DN 025 W/HC /-SO882 | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| >0400 DN 025 W/HC (USE 2213984) | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 025 W/HC /-V-SO882 | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 025 XSX /-V | HYDAC | 25 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | XSX=Stat-X | — | |
| 0400 DN 050 KS | HYDAC | 50 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | KS=Cooling Lubricant | — | |
| 0400 DN 050 W/HC /-SO882 | HYDAC | 50 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| >0400 DN 050 W/HC (USE 2213985) | HYDAC | 50 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 050 W/HC /-V-SO882 | HYDAC | 50 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 100 W/HC /-SO882 | HYDAC | 100 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| >0400 DN 100 W/HC (USE 2213986) | HYDAC | 100 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 100 W/HC /-V-SO882 | HYDAC | 100 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 200 W/HC /-SO882 | HYDAC | 200 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 200 W/HC /-V-SO882 | HYDAC | 200 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 200 W/HC /-V | HYDAC | 200 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0400 DN 200 W/HC | HYDAC | 200 µm | 80 mm (3.1 in) | 400 mm (15.7 in) | W/HC=Stainless Steel Wire Mesh | — | |
| 0500 D 003 BH4HC | HYDAC | 3 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060362, MF0920735 | |
| 0500 D 003 ON | HYDAC | 3 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | ON=Optimicron low-press. | — | |
| 0500 D 005 BH4HC | HYDAC | 5 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060364, MF0920737 | |
| 0500 D 005 ON /-SFREE | HYDAC | 5 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | ON=Optimicron low-press. | — | |
| 0500 D 005 ON | HYDAC | 5 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | ON=Optimicron low-press. | — | |
| 0500 D 010 BH4HC /-V | HYDAC | 10 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | BH/HC=Betamicron® High Collapse | — | |
| 0500 D 010 BH4HC | HYDAC | 10 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060366, MF0920730 | |
| 0500 D 010 ON | HYDAC | 10 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | ON=Optimicron low-press. | — | |
| 0500 D 020 BH4HC | HYDAC | 20 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060368, MF0920733 | |
| 0500 D 020 ON | HYDAC | 20 µm | 91 mm (3.6 in) | 254 mm (10.00 in) | ON=Optimicron low-press. | — | |
| 0580 R 003 ON | HYDAC | 3 µm | 95 mm (3.7 in) | 525 mm (20.70 in) | ON=Optimicron low-press. | — | |
| 0580 R 005 ON | HYDAC | 5 µm | 95 mm (3.7 in) | 525 mm (20.70 in) | ON=Optimicron low-press. | — | |
| 0580 R 010 ON | HYDAC | 10 µm | 95 mm (3.7 in) | 525 mm (20.70 in) | ON=Optimicron low-press. | — | |
| 0630 DN 003 BH4HC | HYDAC | 3 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0630 DN 003 BN4HC /-V | HYDAC | 3 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | — | |
| 0630 DN 003 BN4HC | HYDAC | 3 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | Main Filter MF0436202, MF0919445 | |
| 0630 DN 006 BH4HC | HYDAC | 6 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0630 DN 006 BN4HC | HYDAC | 6 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | Main Filter MF0436206, MF0919449 | |
| 0630 DN 010 BH4HC /-V | HYDAC | 10 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0630 DN 010 BH4HC | HYDAC | 10 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BH/HC=Betamicron® High Collapse | — | |
| 0630 DN 010 BN4HC | HYDAC | 10 µm | 100 mm (3.94 in) | 398 mm (15.7 in) | BN/HC=Betamicron® Low Collapse | Main Filter MF0436213, MF0919438 | |
| 0660 D 001 BH4HC /-SFREE | HYDAC | 1 µm | 91 mm (3.6 in) | 329 mm (13 in) | BH/HC=Betamicron® High Collapse | — | |
| 0660 D 001 ON | HYDAC | 1 µm | 91 mm (3.6 in) | 330 mm (13 in) | ON=Optimicron low-press. | Main Filter MF0920793 | |
| 0660 D 003 BH4HC /-V | HYDAC | 3 µm | 91 mm (3.6 in) | 329 mm (13 in) | BH/HC=Betamicron® High Collapse | — | |
| 0660 D 003 BH4HC | HYDAC | 3 µm | 91 mm (3.6 in) | 329 mm (13 in) | BH/HC=Betamicron® High Collapse | Main Filter MF0060477, MF0920800 | |
| 0660 D 003 OH/PS | HYDAC | 3 µm | 91 mm (3.6 in) | 330 mm (13 in) | OH/PS=OptimicronH Pulse | — | |
| 0660 D 003 ON/PS | HYDAC | 3 µm | 91 mm (3.6 in) | 330 mm (13 in) | ON/PS=OptimicronN Pulse | — |